Filter Severity

Edition: Enterprise

Description

The Severity Filter processor can be used to filter out logs that do not meet a given severity threshold.

Supported Types

MetricsLogsTraces

Configuration Table

ParameterTypeDefaultDescription
severityenumTRACEMinimum severity to match. Log entries with lower severities will be filtered.

Valid severity levels:

  • TRACE
  • INFO
  • WARN
  • ERROR
  • FATAL

Example Configuration

Filter out INFO and TRACE logs.

Web Interface

filter_severity

Standalone Processor

apiVersion: bindplane.observiq.com/v1
kind: Processor
metadata:
  id: severity-filter
  name: severity-filter
spec:
  type: filter_severity
  parameters:
    - name: severity
      value: WARN

Configuration with Embedded Processor

apiVersion: bindplane.observiq.com/v1
kind: Configuration
metadata:
  id: severity-filter
  name: severity-filter
  labels:
    platform: linux
spec:
  sources:
    - type: journald
      parameters:
        - name: units
          value: []
        - name: directory
          value: ""
        - name: priority
          value: info
        - name: start_at
          value: end
      processors:
        - type: filter_severity
          parameters:
            - name: severity
              value: WARN
  selector:
    matchLabels:
      configuration: severity-filter